Welcome to National Stock Numbers Quotes, your go-to solution for Test Stand Hydrauli components by Warner Robins Air Logistics Center. With over 2 billion ready-to-purchase products in our inventory, customers can easily meet rigid time constraints and inflexible budget parameters. National Stock Numbers Quotes maintains a diverse database of items that suit a myriad of industry verticals, including aerospace, defense, and civil sectors, among others. On this page, you can submit a quote request for part number PD07WRGBZOENF10-TYPE2E with NSN 4920015597446 to receive a customized solution in as little as 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
At National Stock Numbers Quotes, we make it a priority to meet our customers’ operational requirements, so we keep catalogs fully stocked with in-demand NSN parts like those with the FSC 4920 Aircraft Maintenance And Repair Shop Specialized Equipment by Warner Robins Air Logistics Center. For additional specification regarding your part needs, you can also find a wide range of items by their respective CAGE Code, such as 98752, and many other designations for your ease-of-search. Kick off the procurement process with a competitive quote for NSN 4920-01-559-7446 today and see why customers continuously rely on National Stock Numbers Quotes time and time again. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock!
MRC | Criteria | Characteristic |
---|---|---|
CGYK | ENGINE DRIVEN HYDRAULIC PUMP TESTING DESIGN FEATURE | NOT INCLUDED |
CHGQ | FILTERING SYSTEM | INCLUDED |
AAYJ | HYDRAULIC FLUID FLOW RATE | 40.0 GALLONS PER MINUTE |
BGST | PRESSURE RATING | 250.0 POUNDS PER SQUARE INCH MINIMUM AND 5000.0 POUNDS PER SQUARE INCH MAXIMUM |
ACDC | CURRENT TYPE | AC |
ATJK | POWER SOURCE | ELECTRIC MOTOR |
FREQ | FREQUENCY IN HERTZ | 50.0 AND 60.0 |
SR-5 | MANUFACTURERS CODE | 98752 |
AMQY | INSTALLATION DESIGN | PORTABLE |
AYJM | ACCUMULATOR | NOT INCLUDED |
SR-5 | THE MANUFACTURERS DATA | |
RDAL | III REFERENCE DATA AND LITERATURE | PD07WRGBZOENF10 |
FAAZ | PHASE | THREE |
ELEC | VOLTAGE IN VOLTS | 380.0 AND 416.0 |
SR-5 | DESIGN CONTROL REFERENCE | PD07WRGBZOENF10/TYPE2E |
FCLS | III FUNCTIONAL CLASSIFICATION | AA-9.3 |
FTLD | III FUNCTIONAL DESCRIPTION | TYPE 2 DUAL SYSTEM ELECTRIC MOTOR DRIVEN UNIVERSAL HYDRAULIC TEST STAND USED IN GROUND CHECKING AND MAINTENANCE OF AIRCRAFT HYDRAULIC SYSTEMS |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | UNIVERSAL HYDRAULIC TEST STAND-DUAL SYSTEM,TRAILER MOUNTED |
AGAV | III END ITEM IDENTIFICATION | GENERAL AIRCRAFT |
ALBY | USAGE DESIGN | AIRCRAFT HYDRAULIC SYSTEM |
CGYM | PRESSURE MANIFOLD SUBCIRCUIT | INCLUDED |
CHGN | SUBCIRCUIT QUANTITY AND MAXIMUM OPERATING PRESSURE | TWO 5000PSI |