Welcome to National Stock Numbers Quotes, your go-to solution for Reactor Transformer components by Rockwell Collins Aerospace. With over 2 billion ready-to-purchase products in our inventory, customers can easily meet rigid time constraints and inflexible budget parameters. National Stock Numbers Quotes maintains a diverse database of items that suit a myriad of industry verticals, including aerospace, defense, and civil sectors, among others. On this page, you can submit a quote request for part number 217-0090-030 with NSN 5950013544735 to receive a customized solution in as little as 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
At National Stock Numbers Quotes, we make it a priority to meet our customers’ operational requirements, so we keep catalogs fully stocked with in-demand NSN parts like those with the FSC 5950 Coils and Transformers by Rockwell Collins Aerospace. For additional specification regarding your part needs, you can also find a wide range of items by their respective CAGE Code, such as 95105, and many other designations for your ease-of-search. Kick off the procurement process with a competitive quote for NSN 5950-01-354-4735 today and see why customers continuously rely on National Stock Numbers Quotes time and time again. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-354-4735 Item PartTypeName: REACTOR-TRANSFORMER | 5950 | 013544735 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
27-005-03 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHY | TURN QUANTITY | 12 1ST COMPONENT 3RD SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.900 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACYV | INDUCTANCE RATING | 3.50 MICROHENRIES MAXIMUM 1ST COMPONENT 1ST PRIMARY |
ACYV | INDUCTANCE RATING | 3.50 MICROHENRIES MAXIMUM 1ST COMPONENT 2ND SECONDARY |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL 1ST COMPONENT |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL 2ND COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD CONNECTED TO SECONDARY TERMINAL 2ND COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CQPZ | WINDING CONDUCTOR SIZE | 0.01003 INCHES AMERICAN WIRE GAGE 1ST COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.020 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.045 1ST COMPONENT 2ND PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.150 1ST COMPONENT 1ST PRIMARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHY | TURN QUANTITY | 20 1ST COMPONENT 1ST SECONDARY |
ABHY | TURN QUANTITY | 32 1ST COMPONENT 2ND PRIMARY |
ABHY | TURN QUANTITY | 4 1ST COMPONENT 2ND SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT 1ST PRIMARY AND WINDING TURNS 1ST COMPONENT 1ST PRIMARY |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE WINDING AND WINDING TURNS 2ND COMPONENT SINGLE WINDING |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY 2ND COMPONENT AND 3 SECONDARY 2ND COMPONENT |
CQPZ | WINDING CONDUCTOR SIZE | 0.01003 INCHES AMERICAN WIRE GAGE 2ND COMPONENT SINGLE WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 16 PIN |
ABHY | TURN QUANTITY | 12 1ST COMPONENT 1ST PRIMARY |
ABKW | OVERALL HEIGHT | 1.400 INCHES MAXIMUM |
ACYV | INDUCTANCE RATING | 5.50 MICROHENRIES MAXIMUM 1ST COMPONENT 3RD SECONDARY |
ACYV | INDUCTANCE RATING | 8.50 MICROHENRIES MAXIMUM 1ST COMPONENT 1ST SECONDARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE 2ND COMPONENT |
ADAQ | BODY LENGTH | 3.400 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.000 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT ALL SECONDARY AND WINDING TURNS 1ST COMPONENT ALL SECONDARY |
BKPL | RATING METHOD | WINDING TURNS 1ST COMPONENT 2ND PRIMARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01003 INCHES AMERICAN WIRE GAGE 1ST COMPONENT 2ND PRIMARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 1ST COMPONENT 1ST PRIMARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.020 1ST COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.150 1ST COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.150 2ND COMPONENT SINGLE WINDING |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
ABHY | TURN QUANTITY | 50 2ND COMPONENT SINGLE WINDING |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 1ST COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | INTERNAL SHIELD BROUGHT OUT AND CONNECTED TO PRIMARY TERMANAL |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote