Welcome to National Stock Numbers Quotes, your go-to solution for Transformer Power components by Quality Transformer Corp. With over 2 billion ready-to-purchase products in our inventory, customers can easily meet rigid time constraints and inflexible budget parameters. National Stock Numbers Quotes maintains a diverse database of items that suit a myriad of industry verticals, including aerospace, defense, and civil sectors, among others. On this page, you can submit a quote request for part number R-2760 with NSN 5950013376426 to receive a customized solution in as little as 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
At National Stock Numbers Quotes, we make it a priority to meet our customers’ operational requirements, so we keep catalogs fully stocked with in-demand NSN parts like those with the FSC 5950 Coils and Transformers by Quality Transformer Corp. For additional specification regarding your part needs, you can also find a wide range of items by their respective CAGE Code, such as 28262, and many other designations for your ease-of-search. Kick off the procurement process with a competitive quote for NSN 5950-01-337-6426 today and see why customers continuously rely on National Stock Numbers Quotes time and time again. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-337-6426 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013376426 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
R-2760 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.700 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.740 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.144 INCHES MINIMUM SINGLE GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 240.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 12 TAB,SOLDER LUG |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 270.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 230.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKW | OVERALL HEIGHT | 2.100 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.178 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.198 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 2.260 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CRBZ | WINDING OPERATING CURRENT | 410.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |