Welcome to National Stock Numbers Quotes, your go-to solution for Transformer Assembly components by Nimikkeistokeskus Ncb Finland. With over 2 billion ready-to-purchase products in our inventory, customers can easily meet rigid time constraints and inflexible budget parameters. National Stock Numbers Quotes maintains a diverse database of items that suit a myriad of industry verticals, including aerospace, defense, and civil sectors, among others. On this page, you can submit a quote request for part number 10132963 with NSN 5950013398204 to receive a customized solution in as little as 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
At National Stock Numbers Quotes, we make it a priority to meet our customers’ operational requirements, so we keep catalogs fully stocked with in-demand NSN parts like those with the FSC 5950 Coils and Transformers by Nimikkeistokeskus Ncb Finland. For additional specification regarding your part needs, you can also find a wide range of items by their respective CAGE Code, such as A486G, and many other designations for your ease-of-search. Kick off the procurement process with a competitive quote for NSN 5950-01-339-8204 today and see why customers continuously rely on National Stock Numbers Quotes time and time again. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-339-8204 Item PartTypeName: TRANSFORMER ASSEMBLY | 5950 | 013398204 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
10132963 | 5 | 9 | 6 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 3.570 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.187 INCHES NOMINAL 1ST GROUP |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 2ND COMPONENT |
ADAT | BODY WIDTH | 3.440 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.500 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
AXGY | MOUNTING METHOD | SLOT 1ST GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE 2ND GROUP |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 3RD SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 4 SECONDARY 1ST COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 3RD COMPONENT AND 3 SECONDARY 3RD COMPONENT |
CBBL | FEATURES PROVIDED | W/RECTIFIER |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES AC NOMINAL 2ND COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 35.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.090 2ND COMPONENT 4TH SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.100 3RD COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT SINGLE PRIMARY |
CRMJ | WINDING POWER RATING | 0.2 VOLTS-AMPERES 3RD COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 18.03 VOLTS-AMPERES 2ND COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 3535.0 VOLTS-AMPERES 2ND COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 530.25 AC VOLTS NOMINAL 1ST COMPONENT 4TH SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.2 AMPERES DC NOMINAL 3RD COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.280 2ND COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 130.00 DC VOLTS MINIMUM 3RD COMPONENT 2ND SECONDARY AND 137.00 DC VOLTS MAXIMUM 3RD COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.55 AC VOLTS NOMINAL 3RD COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 16.26 AC VOLTS NOMINAL 3RD COMPONENT 1ST SECONDARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 5.375 INCHES NOMINAL 3RD MOUNTING FACILITY SINGLE CENTER GROUP |
AFHM | MOUNTING TAB WIDTH | 0.625 INCHES NOMINAL |
AXGY | MOUNTING METHOD | TAB 3RD GROUP |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 1.200 2ND COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 2.750 1ST COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 5245.8 VOLTS-AMPERES 2ND COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 70.70 AC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 36 WIRE LEAD |
CWJS | WINDING OPERATING VOLTAGE | 6.01 AC VOLTS NOMINAL 2ND COMPONENT 4TH SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 6.030 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.500 INCHES NOMINAL 2ND GROUP |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL ALL COMPONENTS |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 3RD COMPONENT AND INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL 3RD COMPONENT |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 4.500 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 2 2ND GROUP |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT 4TH SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 1ST SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT AND 4 SECONDARY 2ND COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.01 AMPERES AC NOMINAL 3RD COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 0.035 AMPERES AC NOMINAL 3RD COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES AC NOMINAL 1ST COMPONENT 4TH SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.040 3RD COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.060 1ST COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 12.000 2ND COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 159.07 VOLTS-AMPERES 1ST COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 160.2 VOLTS-AMPERES 3RD COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 300.5 VOLTS-AMPERES 2ND COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 7.47 VOLTS-AMPERES 3RD COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 14.14 AC VOLTS NOMINAL 2ND COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 149.88 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.55 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 178.16 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY AND 195.84 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY AND 213.57 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.01 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote