Welcome to National Stock Numbers Quotes, your go-to solution for Waveguideassembly components by Microwave Engineering Corporation. With over 2 billion ready-to-purchase products in our inventory, customers can easily meet rigid time constraints and inflexible budget parameters. National Stock Numbers Quotes maintains a diverse database of items that suit a myriad of industry verticals, including aerospace, defense, and civil sectors, among others. On this page, you can submit a quote request for part number R170 with NSN 5985013424022 to receive a customized solution in as little as 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
At National Stock Numbers Quotes, we make it a priority to meet our customers’ operational requirements, so we keep catalogs fully stocked with in-demand NSN parts like those with the FSC 5985 Antennas Waveguides and Related Equipment by Microwave Engineering Corporation. For additional specification regarding your part needs, you can also find a wide range of items by their respective CAGE Code, such as 06351, and many other designations for your ease-of-search. Kick off the procurement process with a competitive quote for NSN 5985-01-342-4022 today and see why customers continuously rely on National Stock Numbers Quotes time and time again. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-342-4022 Item PartTypeName: WAVEGUIDE ASSEMBLY | 5985 | 013424022 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | S | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3452598-1 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AHSZ | FLANGE OUTSIDE WIDTH | 1.360 INCHES MINIMUM ALL FLANGES AND 1.390 INCHES MAXIMUM ALL FLANGES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.0960 INCHES MINIMUM ALL FLANGES SECOND CONNECTION FACILITY AND 0.0965 INCHES MAXIMUM ALL FLANGES SECOND CONNECTION FACILITY |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.25 |
AHTX | INSERTION LOSS IN DECIBELS | 0.30 |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES ALL FLANGES FIRST CONNECTION FACILITY |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.318 INCHES MINIMUM AND 0.324 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE ALL FLANGES FIRST CONNECTION FACILITY |
FEAT | SPECIAL FEATURES | POWER RATING 800 WATTS AVERAGE |
THSD | THREAD SERIES DESIGNATOR | UNC ALL FLANGES FIRST CONNECTION FACILITY |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDE AND RELATED EQUIPMENT |
AAJF | THREAD DIRECTION | RIGHT-HAND ALL FLANGES FIRST CONNECTION FACILITY |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.0937 INCHES MINIMUM ALL FLANGES THIRD CONNECTION FACILITY AND 0.0939 INCHES MAXIMUM ALL FLANGES THIRD CONNECTION FACILITY |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.788 INCHES MINIMUM AND 0.794 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE ALL FLANGES THIRD CONNECTION FACILITY |
CTFD | WAVEGUIDE LENGTH | 2.500 INCHES NOMINAL |
PMLC | PRECIOUS MATERIAL AND LOCATION | INTERNAL WAVEGUIDE SURFACE SILVER |
SFTT | SURFACE TREATMENT | SILVER SINGLE TUBING SEGMENT INSIDE SURFACES |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.688 INCHES MINIMUM ALL FLANGES AND 0.694 INCHES MAXIMUM ALL FLANGES |
AHTD | FLANGE DEPTH | 0.235 INCHES MINIMUM ALL FLANGES AND 0.265 INCHES MAXIMUM ALL FLANGES |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.688 INCHES MINIMUM AND 0.694 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.418 INCHES MINIMUM AND 0.424 INCHES MAXIMUM |
CXBB | WAVEGUIDE CENTER TO CENTER DISTANCE | 0.800 INCHES NOMINAL |
MATT | MATERIAL | ALUMINUM ALLOY ALL FLANGE |
MATT | MATERIAL | COPPER ALLOY SINGLE TUBING SEGMENT |
PRMT | PRECIOUS MATERIAL | SILVER |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR DOUBLE RIDGED EXTERNAL,RECTANGULAR |
AAJD | THREAD CLASS | 2B ALL FLANGES FIRST CONNECTION FACILITY |
AHSY | FLANGE INSIDE HEIGHT | 0.318 INCHES MINIMUM ALL FLANGES AND 0.324 INCHES MAXIMUM ALL FLANGES |
AHTA | FLANGE OUTSIDE HEIGHT | 1.360 INCHES MINIMUM ALL FLANGES AND 1.390 INCHES MAXIMUM ALL FLANGES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE ALL FLANGES SECOND CONNECTION FACILITY |
CTCJ | FLANGE STYLE | CONTACT,DOUBLE RIDGE TYPE ALL FLANGES |
FLEX | FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
STYL | STYLE DESIGNATOR | OFFSET BEND TYPE |