Find Part Number 4300M With NSN 6630-01-364-8555 by Mallinckrodt Sensor Systems Inc!

Part Number: 4300M
NIIN: 013648555
Item Name : Analyzer Blood Gas
CAGE Code: 0CNN1
FSG: 66 Instruments and Laboratory Equipment
Country: USA
NCB Code: 01

Welcome to National Stock Numbers Quotes, your go-to solution for Analyzer Blood Gas components by Mallinckrodt Sensor Systems Inc. With over 2 billion ready-to-purchase products in our inventory, customers can easily meet rigid time constraints and inflexible budget parameters. National Stock Numbers Quotes maintains a diverse database of items that suit a myriad of industry verticals, including aerospace, defense, and civil sectors, among others. On this page, you can submit a quote request for part number 4300M with NSN 6630013648555 to receive a customized solution in as little as 15 minutes or less.

Note : We Will Not Share Your Information To Any Third Parties.

Product Details

“*” Required Fields Are Compulsory

Contact Information

   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Disclaimer: This is a quotation for the goods listed above. This quotation is meant as an estimate and does not reflect a final bill or invoice. All quotations are subject to change until acceptance by ASAP Semiconductor of a binding Purchase Order, and quotations may be withdrawn or revised at the sole discretion of ASAP Semiconductor. This quotation is subject to the ASAP Semiconductor Terms & Conditions available at https://www.asapsemi.com/terms-conditions.aspx . All United States Government and Department of Defense bids are quoted as CAGE code 6RE77 from ASAP Semiconductor’s Anaheim, California facility. Any quotation from ASAP Semiconductor without 6RE77 is void.

Upload RFQ SHEET

At National Stock Numbers Quotes, we make it a priority to meet our customers’ operational requirements, so we keep catalogs fully stocked with in-demand NSN parts like those with the FSC 6630 Chemical Analysis Instruments by Mallinckrodt Sensor Systems Inc. For additional specification regarding your part needs, you can also find a wide range of items by their respective CAGE Code, such as 0CNN1, and many other designations for your ease-of-search. Kick off the procurement process with a competitive quote for NSN 6630-01-364-8555 today and see why customers continuously rely on National Stock Numbers Quotes time and time again. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock! 

Characteristics Data of NSN 6630-01-364-8555, 6630013648555

MRCCriteriaCharacteristic
DPTHDepth18.300 INCHES
ELECVoltage In Volts120.0 AND 230.0
MRCDecoded RequirementClear Text Reply
CBBLFeatures ProvidedDIGITAL DISPLAY SCREEN AND INTEGRAL PRINTER AND SELF-CALIBRATION
CXCYPart Name Assigned By Controlling AgencyBLOOD GAS ANALYZER 120/230V 50/60 HZ AC:
ACDCCurrent TypeAC
CYFVMethod Of AnalysisPOLAROGRAPHIC AND POTENTIOMETRIC/ION SELECTIVE ELECTRODE
ACZBFrequency Rating50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL
CYFYAnalysis Test/Measurement RangePO2 0 TO 600 MMHG; PH 6.8 TO 7.8; PCO2 8 TO 99 MMHG; K 0.1 TO 9.9 MMOL/L; NA 100 TO 200 MMOL/L; CA 0.25 TO 4.25 MMOL/L; HCT 10 TO 75 PCT; HC03 3.0 60 MMOL/L TCO2 3.0 TO 60 MMOL/L; BASE EXCESS -30 TO +30 MMOL/L; O2 SAT 30 TO 90 PCT.
CYHMTest Sample/Specimen TypeWHOLE BLOOD
ABRNHeight8.400 INCHES
WDTHWidth9.100 INCHES
AQXYTest Type For Which DesignedBLOOD GASES AND ELECTROLYTES,HC03,HCT,BASE EXCESS AND 02 SAT
CYFZTest Sample/Specimen Size0.5 ML
FEATSpecial FeaturesUTILIZES A DISPOSABLE CARTRIDGE/TEST PACK THAT CONTAINS ALL ELECTRODES, CALIBRATING SOLUTIONS AND GASES PLUS A WASTE BAG FOR PROCESSED BLOOD, CALIBRATING AND QC SOLUTIONS. THE CARTRIDGE/TEST PACK SHALL ELIMINATE THE NEED FOR GAS TANKS EXTERNAL SOLUTIONS, AND ELECTRODE MAINTENANCE. SHALL BE PRE-PROGRAMED TO AUTOMATICALLY PERFORM TWO-POINT CALIBRATIONS EVERY HOUR AND ONE-POINT CALIBRATIONS EVERY 90 SECONDS. CAPABLE OF AUTOMATIC ASPIRATION OF THE SAMPLE AND TO PROCESS, DISPLAY, AND PRINT THE RESULTS IN LESS THAN 2 MINUTES. SHALL BE SUITABLE FOR THE FIELD ENVIRONMENT.

Related NSN Components of 4300M

Semiconductor’s Certifications and Memberships

No China Banner
No China Parts The only independent
distributor with a
NO CHINA SOURCING Pledge
USA Flag Banner
USA Flag
  • All Orders are Fulfilled in the U.S.A.
  • All shipments must comply with U.S.A. export laws.
  • No exceptions.
Fallen Heros Banner
Fallen Heros Fund

“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.