Welcome to National Stock Numbers Quotes, your go-to solution for Transformerassembly components by Magnetika Inc. With over 2 billion ready-to-purchase products in our inventory, customers can easily meet rigid time constraints and inflexible budget parameters. National Stock Numbers Quotes maintains a diverse database of items that suit a myriad of industry verticals, including aerospace, defense, and civil sectors, among others. On this page, you can submit a quote request for part number TW65004-100 with NSN 5950011303608 to receive a customized solution in as little as 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
At National Stock Numbers Quotes, we make it a priority to meet our customers’ operational requirements, so we keep catalogs fully stocked with in-demand NSN parts like those with the FSC 5950 Coils and Transformers by Magnetika Inc. For additional specification regarding your part needs, you can also find a wide range of items by their respective CAGE Code, such as 02640, and many other designations for your ease-of-search. Kick off the procurement process with a competitive quote for NSN 5950-01-130-3608 today and see why customers continuously rely on National Stock Numbers Quotes time and time again. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-130-3608 Item PartTypeName: TRANSFORMER ASSEMBLY | 5950 | 011303608 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
TW65004-100 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC MAXIMUM 1ST COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC MAXIMUM 2ND COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES AC MAXIMUM 2ND COMPONENT SINGLE SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 400.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES AC MAXIMUM 1ST COMPONENT 4TH SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.0065 1ST COMPONENT 4TH SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.040 1ST COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.040 2ND COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.048 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.100 1ST COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.350 1ST COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 3.000 2ND COMPONENT SINGLE SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 3.000 3RD COMPONENT SINGLE SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; FIVE SECONDARY WINDINGS ON FIRST COMPONENT AND FOUR PRIMARY WINDINGS; ONE SECONDARY WINDING ON THIRD COMPONENT |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 17 PIN |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.600 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.985 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL ALL COMPONENTS |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL ALL COMPONENTS |
ADAQ | BODY LENGTH | 2.525 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.025 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.800 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AGAV | END ITEM IDENTIFICATION | MLRS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT ALL SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT ALL PRIMARY |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT SINGLE SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 5 SECONDARY 1ST COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT AND 1 SECONDARY 2ND COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 4 PRIMARY 3RD COMPONENT AND 1 SECONDARY 3RD COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM 1ST COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 140.0 MILLIAMPERES AC MAXIMUM 3RD COMPONENT SINGLE SECONDARY |