Welcome to National Stock Numbers Quotes, your go-to solution for Relay Electromagnet components by Inspektorat Wsparcia Sil Zbrojnych. With over 2 billion ready-to-purchase products in our inventory, customers can easily meet rigid time constraints and inflexible budget parameters. National Stock Numbers Quotes maintains a diverse database of items that suit a myriad of industry verticals, including aerospace, defense, and civil sectors, among others. On this page, you can submit a quote request for part number 5945PL1063684 with NSN 5945013448943 to receive a customized solution in as little as 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
At National Stock Numbers Quotes, we make it a priority to meet our customers’ operational requirements, so we keep catalogs fully stocked with in-demand NSN parts like those with the FSC 5945 Relays and Solenoids by Inspektorat Wsparcia Sil Zbrojnych. For additional specification regarding your part needs, you can also find a wide range of items by their respective CAGE Code, such as 9009H, and many other designations for your ease-of-search. Kick off the procurement process with a competitive quote for NSN 5945-01-344-8943 today and see why customers continuously rely on National Stock Numbers Quotes time and time again. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-344-8943 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 013448943 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
MS27751-19 | 5 | 2 | 2 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 3.130 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.440 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CBME | CUBIC MEASURE | 0.707 CUBIC INCHES |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE MOUNTING FACILITY |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC LAMP LOAD AND 10.0 AMPERES DC LAMP LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 60.0 AMPERES AC RESISTIVE LOAD AND 50.0 AMPERES DC RESISTIVE LOAD |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
TTQY | TERMINAL TYPE AND QUANTITY | 13 THREADED STUD ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS27751 GOVERNMENT STANDARD |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 2.500 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.990 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 2.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.990 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 2.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.168 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.175 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 160.0 MILLIAMPERES DC SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES DC INDUCTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 40.0 AMPERES AC MOTOR LOAD AND 20.0 AMPERES DC MOTOR LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 PROBE AC LAMP LOAD AND 1.0 PROBE DC LAMP LOAD |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 PROBE AC INDUCTIVE LOAD AND 3.0 PROBE DC INDUCTIVE LOAD |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 PROBE AC RESISTIVE LOAD AND 3.0 PROBE DC RESISTIVE LOAD |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE MOUNTING FACILITY |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APNA | WINDING DC RESISTANCE RATING | 200.0 OHMS NOMINAL SINGLE WINDING |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote