Welcome to National Stock Numbers Quotes, your go-to solution for Filter Band Pass components by Filter Research Corp. With over 2 billion ready-to-purchase products in our inventory, customers can easily meet rigid time constraints and inflexible budget parameters. National Stock Numbers Quotes maintains a diverse database of items that suit a myriad of industry verticals, including aerospace, defense, and civil sectors, among others. On this page, you can submit a quote request for part number 10B70 with NSN 5915011527225 to receive a customized solution in as little as 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
At National Stock Numbers Quotes, we make it a priority to meet our customers’ operational requirements, so we keep catalogs fully stocked with in-demand NSN parts like those with the FSC 5915 Filters and Networks by Filter Research Corp. For additional specification regarding your part needs, you can also find a wide range of items by their respective CAGE Code, such as 57996, and many other designations for your ease-of-search. Kick off the procurement process with a competitive quote for NSN 5915-01-152-7225 today and see why customers continuously rely on National Stock Numbers Quotes time and time again. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-152-7225 Item PartTypeName: FILTER,BAND PASS | 5915 | 011527225 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
SM-A-838216-10 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM 5TH BAND PASS AND 30.0 MAXIMUM 5TH BAND PASS 5TH FUNCTION |
CRST | BODY SURFACE TREATMENT | TIN |
FEAT | SPECIAL FEATURES | FIVE FILTERED FUNCTIONS; UNPACKAGED UNIT WEIGHT: OZ4.250 |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
ABKW | OVERALL HEIGHT | 0.779 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.030 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.280 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.560 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.500 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 2000.0 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.750 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -29.0 TO 85.0 DEG CELSIUS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 1.0 KILOHERTZ 3RD BAND PASS 3RD FUNCTION |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 1.05 KILOHERTZ 4TH BAND PASS 4TH FUNCTION |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 1.1 KILOHERTZ 5TH BAND PASS 5TH FUNCTION |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 900.0 HERTZ 1ST BAND PASS 1ST FUNCTION |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 941.0 HERTZ 2ND BAND PASS 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 KILOHMS 1ST BAND PASS 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 KILOHMS 2ND BAND PASS 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 KILOHMS 3RD BAND PASS 3RD FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 KILOHMS 4TH BAND PASS 4TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 KILOHMS 5TH BAND PASS 5TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 100.0 KILOHMS 1ST BAND PASS 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 100.0 KILOHMS 2ND BAND PASS 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 100.0 KILOHMS 3RD BAND PASS 3RD FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 100.0 KILOHMS 4TH BAND PASS 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 100.0 KILOHMS 5TH BAND PASS 5TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST BAND PASS 1ST FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND BAND PASS 2ND FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD BAND PASS 3RD FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH BAND PASS 4TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH BAND PASS 5TH FUNCTION |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 14 PIN |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 1ST BAND PASS 1ST FUNCTION |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 2ND BAND PASS 2ND FUNCTION |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 3RD BAND PASS 3RD FUNCTION |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 4TH BAND PASS 4TH FUNCTION |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 5TH BAND PASS 5TH FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 5 PIN OUTPUT 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 1.021 KILOHERTZ 4TH BAND PASS AND 1.033 KILOHERTZ 4TH BAND PASS AND 1.068 KILOHERTZ 4TH BAND PASS AND 1.08 KILOHERTZ 4TH BAND PASS 4TH FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 1.069 KILOHERTZ 5TH BAND PASS AND 1.081 KILOHERTZ 5TH BAND PASS AND 1.119 KILOHERTZ 5TH BAND PASS AND 1.132 KILOHERTZ 5TH BAND PASS 5TH FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 876.00 HERTZ 1ST BAND PASS AND 885.00 HERTZ 1ST BAND PASS AND 915.00 HERTZ 1ST BAND PASS AND 924.00 HERTZ 1ST BAND PASS 1ST FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 916.00 HERTZ 2ND BAND PASS AND 926.00 HERTZ 2ND BAND PASS AND 957.00 HERTZ 2ND BAND PASS AND 967.00 HERTZ 2ND BAND PASS 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 970.00 HERTZ 3RD BAND PASS AND 983.00 HERTZ 3RD BAND PASS AND 1.017 KILOHERTZ 3RD BAND PASS AND 1.031 KILOHERTZ 3RD BAND PASS 3RD FUNCTION |
CQRG | BODY MATERIAL | METAL |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 1.033 KILOHERTZ 4TH BAND PASS AND 1.068 KILOHERTZ 4TH BAND PASS 4TH FUNCTION |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 1.081 KILOHERTZ 5TH BAND PASS AND 1.119 KILOHERTZ 5TH BAND PASS 5TH FUNCTION |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 885.00 HERTZ 1ST BAND PASS AND 915.00 HERTZ 1ST BAND PASS 1ST FUNCTION |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 926.00 HERTZ 2ND BAND PASS AND 957.00 HERTZ 2ND BAND PASS 2ND FUNCTION |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 983.00 HERTZ 3RD BAND PASS AND 1.017 KILOHERTZ 3RD BAND PASS 3RD FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM 1ST BAND PASS AND 30.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM 2ND BAND PASS AND 30.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM 3RD BAND PASS AND 30.0 MAXIMUM 3RD BAND PASS 3RD FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM 4TH BAND PASS AND 30.0 MAXIMUM 4TH BAND PASS 4TH FUNCTION |