Welcome to National Stock Numbers Quotes, your go-to solution for Transformer Power components by Electronic Transformer Corp. With over 2 billion ready-to-purchase products in our inventory, customers can easily meet rigid time constraints and inflexible budget parameters. National Stock Numbers Quotes maintains a diverse database of items that suit a myriad of industry verticals, including aerospace, defense, and civil sectors, among others. On this page, you can submit a quote request for part number C16320 with NSN 5950005320900 to receive a customized solution in as little as 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
At National Stock Numbers Quotes, we make it a priority to meet our customers’ operational requirements, so we keep catalogs fully stocked with in-demand NSN parts like those with the FSC 5950 Coils and Transformers by Electronic Transformer Corp. For additional specification regarding your part needs, you can also find a wide range of items by their respective CAGE Code, such as 72149, and many other designations for your ease-of-search. Kick off the procurement process with a competitive quote for NSN 5950-00-532-0900 today and see why customers continuously rely on National Stock Numbers Quotes time and time again. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-532-0900 Item PartTypeName: TRANSFORMER,POWER | 5950 | 005320900 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
10039725-103 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 0.855 INCHES MINIMUM AND 0.855 INCHES MINIMUM AND 0.855 INCHES MINIMUM AND 0.885 INCHES MAXIMUM0.885 INCHES MAXIMUM0.885 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.665 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.665 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.665 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.695 INCHES MAXIMUM SINGLE MO |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.535 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.535 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.535 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.565 INCHES MAXIMUM SINGLE MO |
ABKW | OVERALL HEIGHT | 1.125 INCHES MINIMUM AND 1.125 INCHES MINIMUM AND 1.125 INCHES MINIMUM AND 1.155 INCHES MAXIMUM1.155 INCHES MAXIMUM1.155 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.765 INCHES MINIMUM AND 0.765 INCHES MINIMUM AND 0.765 INCHES MINIMUM AND 0.795 INCHES MAXIMUM0.795 INCHES MAXIMUM0.795 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.111 INCHES MINIMUM SINGLE GROUP AND 0.111 INCHES MINIMUM SINGLE GROUP AND 0.111 INCHES MINIMUM SINGLE GROUP AND 0.121 INCHES MAXIMUM SINGLE GROUP0.121 INCHES MAXIMUM SINGLE GROUP0.121 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 85.0 DEG CELSIUS |
AGAV | END ITEM IDENTIFICATION | TICONDEROGA CLASS CG (47); OLIVER PERRY CLASS FFG; SPRUANCE CLASS DD (963); VIRGINIA CLASS CGN (41); KIDD CLASS DDG; AIRCRAFT,VIKING S-3B |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP2 SINGLE GROUP2 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT1 SECONDARY SINGLE COMPONENT1 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 71.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY28.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
TTQY | TERMINAL TYPE AND QUANTITY | 5 TURRET |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote