Welcome to National Stock Numbers Quotes, your go-to solution for Transformer Power components by Dla Land And Maritime. With over 2 billion ready-to-purchase products in our inventory, customers can easily meet rigid time constraints and inflexible budget parameters. National Stock Numbers Quotes maintains a diverse database of items that suit a myriad of industry verticals, including aerospace, defense, and civil sectors, among others. On this page, you can submit a quote request for part number DHH0054 with NSN 5950004029025 to receive a customized solution in as little as 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
At National Stock Numbers Quotes, we make it a priority to meet our customers’ operational requirements, so we keep catalogs fully stocked with in-demand NSN parts like those with the FSC 5950 Coils and Transformers by Dla Land And Maritime. For additional specification regarding your part needs, you can also find a wide range of items by their respective CAGE Code, such as 16236, and many other designations for your ease-of-search. Kick off the procurement process with a competitive quote for NSN 5950-00-402-9025 today and see why customers continuously rely on National Stock Numbers Quotes time and time again. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-402-9025 Item PartTypeName: TRANSFORMER,POWER | 5950 | 004029025 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
SK2264 | 6 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 6.062 INCHES NOMINAL6.062 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 57.0 HERTZ MINIMUM SINGLE COMPONENT AND 57.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT63.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.312 INCHES NOMINAL4.312 INCHES NOMINAL |
ADAT | BODY WIDTH | 3.688 INCHES NOMINAL3.688 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP0.190 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 0.2 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1700.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY325.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY105.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS NO |
CWJS | WINDING OPERATING VOLTAGE | 1700.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY1700.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY325.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY1700.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | 1PRIMARY WINDING; 5SECONDARY WINDINGS |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 14 TAB,SOLDER LUG |