Welcome to National Stock Numbers Quotes, your go-to solution for Transformer Power components by Bae Systems Inc. With over 2 billion ready-to-purchase products in our inventory, customers can easily meet rigid time constraints and inflexible budget parameters. National Stock Numbers Quotes maintains a diverse database of items that suit a myriad of industry verticals, including aerospace, defense, and civil sectors, among others. On this page, you can submit a quote request for part number 243157P2 with NSN 5950001653694 to receive a customized solution in as little as 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
At National Stock Numbers Quotes, we make it a priority to meet our customers’ operational requirements, so we keep catalogs fully stocked with in-demand NSN parts like those with the FSC 5950 Coils and Transformers by Bae Systems Inc. For additional specification regarding your part needs, you can also find a wide range of items by their respective CAGE Code, such as 94117, and many other designations for your ease-of-search. Kick off the procurement process with a competitive quote for NSN 5950-00-165-3694 today and see why customers continuously rely on National Stock Numbers Quotes time and time again. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-165-3694 Item PartTypeName: TRANSFORMER,POWER | 5950 | 001653694 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
9216 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.740 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.927 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.947 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 2.220 INCHES MINIMUM AND 2.280 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.100 INCHES MINIMUM SINGLE GROUP AND 0.160 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 446.5 VOLT-AMPERE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.970 INCHES MINIMUM AND 3.030 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.280 INCHES MINIMUM AND 1.340 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | OPEN |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | BRACKET SINGLE GROUP AND SLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.8 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.5 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 900.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 238.7 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 24.1 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 45.4 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 48.3 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 113.00 AC VOLTS MINIMUM AND 195.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 15.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 23.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; SIX SECONDARY WINDINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 22 WIRE LEAD |