Welcome to National Stock Numbers Quotes, your go-to solution for Power Supply components by Ametek Programmable Power Inc. With over 2 billion ready-to-purchase products in our inventory, customers can easily meet rigid time constraints and inflexible budget parameters. National Stock Numbers Quotes maintains a diverse database of items that suit a myriad of industry verticals, including aerospace, defense, and civil sectors, among others. On this page, you can submit a quote request for part number AT8-04-01-01-01-2068 with NSN 6130013587701 to receive a customized solution in as little as 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
At National Stock Numbers Quotes, we make it a priority to meet our customers’ operational requirements, so we keep catalogs fully stocked with in-demand NSN parts like those with the FSC 6130 Converters Electrical Non Rotating by Ametek Programmable Power Inc. For additional specification regarding your part needs, you can also find a wide range of items by their respective CAGE Code, such as 25965, and many other designations for your ease-of-search. Kick off the procurement process with a competitive quote for NSN 6130-01-358-7701 today and see why customers continuously rely on National Stock Numbers Quotes time and time again. For one-on-one assistance, contact us via phone or email at any time; we are available around the clock!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-358-7701 Item PartTypeName: POWER SUPPLY | 6130 | 013587701 | N | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | 0 | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AT8-04-01-01-01-02-2068 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
APNX | INPUT VOLTAGE RATING | 230.0 AC POUNDS PER HOUR WET 2ND ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 320.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
CWGH | OUTPUT CURRENT RATING | 10.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 12.0 DC AMPERES NOMINAL 4TH POWER OUTPUT |
AGAV | END ITEM IDENTIFICATION | LASER NAVY MAV UPGRADE |
ABHP | OVERALL LENGTH | 21.000 INCHES NOMINAL |
ANPM | INPUT PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 115.0 AC POUNDS PER HOUR WET 1ST ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 4TH POWER OUTPUT AND 10.0 DC VOLTS MAXIMUM 4TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.6 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 10.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
ABKW | OVERALL HEIGHT | 5.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 19.000 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 20.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 3RD POWER OUTPUT AND 20.0 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/50.0 DEG CELSIUS |
CWWJ | PROGRAM COMPATIBILITY | IEEE 488-1978 |