We appreciate your interest in our selection of parts that fall under the NSN 6630-01-490-3594. Below, top-requested part numbers like 6630NCM010360, 402444, 01-0486, and others are presented alongside their manufacturer for your perusal. In order to receive pricing options on any featured NSN 6630-01-490-3594, simply click on the “RFQ” button next to it and complete the quote request form you are directed to. Be sure to include as many details as you can about your requirements and restrictions alike so our team can best formulate ideal fulfillment options for your consideration.
Owned and operated by the NSN parts supplier ASAP Semiconductor, National Stock Numbers Quotes is only stocked with items that meet strict regulatory and statutory guidelines for export compliance and quality assurance. Moreover, all NSN 6630-01-490-3594 items on this page are sourced from leading manufacturers that we trust and have vetted as necessary. Aside from this steadfast commitment, we also aim to address the unique constraints of customers wherever possible, even if other channels have failed to. If you have any further questions about the services we offer or wish to discuss your needs directly, our representatives are always just a call or email away from assisting you!
Item Name | Analyzer Clinical Chemistry |
Federal Supply Group (FSG) | Instruments and Laboratory Equipment |
Federal Supply Class (FSC) | 6630 Chemical Analysis Instruments |
National Item Identification Number (NIIN) | 01-490-3594 (014903594) |
NCB Code | USA (01) |
Manufacturer | Alfa Wassermann Inc |
MRC | Criteria | Characteristic |
---|---|---|
ELEC | VOLTAGE IN VOLTS | 100.0 AND 120.0 |
DPTH | DEPTH | 25.800 INCHES |
ABRN | HEIGHT | 24.000 INCHES |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | ANALYZER CLINICAL CHEM KINETIC ENZYME/RATE TEST 100/120V50/60HZ |
WDTH | WIDTH | 27.500 INCHES |
FEAT | SPECIAL FEATURES | COMPACT SIZE TABLE TOP DESIGN; REQUIRES 36 INCHES ABOVE ANALYZER; TAKES UP ONLY 4 SQUARE FEET OF SPACE; CLOSED TUBE SAMPLING MINIMIZES RISK FROM BLOOD BORNE PATHOGENS; WITH NEXCT ON-BOARD COMPUTER THAT IDENTIFES AND TRACK SAMPLES AND REAGENT BY LOT NUMBER, EXPIRATION DATE AND AMOUNT OF REAGENT REMAINING FOR AN ULTRA-SECURE, WORRY FREE SYSTEM; UP TO 150 SAMPLES AND 20 SEPARTE TEST REAGENTS MAY BE PLACED ON-BOARD AND EFFECTS SUCH AS EXPOSURE TO LIGHT AND EVAPORATION ARE KEPT TO AN ABSOLUTE MINIMUM; SINGLE PROBE HANDLES ALL SAMPLE AND REAGENT ASPIRATION AND DISPENSE FUNCTIONS; NEW CUVETTE FOR EACH REACTION ELIMINATES CHANCE OF CROSS CONTAMINATION; UP TO 58 CUVETTES CAN BE STORED ON-BOARD AT ANYTIME; IMMEDIATE STAT INTERRUPT; AUTO REPEAT AND DILUTION; MULTI-TASKING INTELLIGENT SOFTWARE OFFERS INDIVIDUAL PROFILE, BATCH OR STAT ASSAYS; INTEGRATED COMPUTER, MONOCHROME MONITOR; EXTERNAL PRINTER AND RELATED SUPPLIES; COLOR CODED PROMPTS; BUILT IN SELF DIAGNOSTICS |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
CYFV | METHOD OF ANALYSIS | KINETIC ENZYME/RATE TEST |
ACDC | CURRENT TYPE | AC |
Relevant Components for NSN - 6630-01-490-3594, 6630014903594 | ||||
6650-01-470-8575 (6650014708575) | 6680-00-420-2338 (6680004202338) | 6685-01-381-6045 (6685013816045) | 6680-01-099-4024 (6680010994024) | |
6665-01-555-9347 (6665015559347) | 6680-01-327-7922 (6680013277922) | 6680-01-172-2374 (6680011722374) | 6625-00-727-8441 (6625007278441) | |
6680-01-602-8030 (6680016028030) | 6625-01-176-3848 (6625011763848) | 6685-01-023-4712 (6685010234712) | 6625-01-388-9493 (6625013889493) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote