Components List of NSN (5950013398204) 5950-01-339-8204

We appreciate your interest in our selection of parts that fall under the NSN 5950-01-339-8204. Below, top-requested part numbers like 321-18050-05, 12020-1, 10132963, 984882-5B, and others are presented alongside their manufacturer for your perusal. In order to receive pricing options on any featured NSN 5950-01-339-8204, simply click on the “RFQ” button next to it and complete the quote request form you are directed to. Be sure to include as many details as you can about your requirements and restrictions alike so our team can best formulate ideal fulfillment options for your consideration.

Owned and operated by the NSN parts supplier ASAP Semiconductor, National Stock Numbers Quotes is only stocked with items that meet strict regulatory and statutory guidelines for export compliance and quality assurance. Moreover, all NSN 5950-01-339-8204 items on this page are sourced from leading manufacturers that we trust and have vetted as necessary. Aside from this steadfast commitment, we also aim to address the unique constraints of customers wherever possible, even if other channels have failed to. If you have any further questions about the services we offer or wish to discuss your needs directly, our representatives are always just a call or email away from assisting you!

Item Name Transformer Assembly
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5950 Coils and Transformers
National Item Identification Number (NIIN) 01-339-8204 (013398204)
NCB Code USA (01)
Manufacturer Oeco Corp, Sora Power Inc, Nimikkeistokeskus Ncb Finland, Raytheon Company
Part Number Manufacturer Item Name RFQ
321-18050-05 oeco corp transformer assembly RFQ
12020-1 sora power inc transformer assembly RFQ
10132963 nimikkeistokeskus ncb finland transformer assembly RFQ
984882-5B raytheon company transformer assembly RFQ

Technical Characteristics of NSN 5950013398204

MRCCriteriaCharacteristic
ABKWOVERALL HEIGHT3.570 INCHES MAXIMUM
ABTDMOUNTING SLOT WIDTH0.187 INCHES NOMINAL 1ST GROUP
ACZXWINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL 2ND COMPONENT
ADATBODY WIDTH3.440 INCHES MAXIMUM
AEHZMAXIMUM OPERATING TEMP130.0 DEG CELSIUS
AEJNDISTANCE BETWEEN MOUNTING FACILITY CENTERS2.500 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP
AXGYMOUNTING METHODSLOT 1ST GROUP
AXGYMOUNTING METHODUNTHREADED HOLE 2ND GROUP
BKPLRATING METHODELECTRICAL ALL COMPONENTS 3RD SECONDARY
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY 1ST COMPONENT AND 4 SECONDARY 1ST COMPONENT
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY 3RD COMPONENT AND 3 SECONDARY 3RD COMPONENT
CBBLFEATURES PROVIDEDW/RECTIFIER
CRBZWINDING OPERATING CURRENT3.0 AMPERES AC NOMINAL 2ND COMPONENT 4TH SECONDARY
CRBZWINDING OPERATING CURRENT35.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 3RD SECONDARY
CRGSDC RESISTANCE RATING IN OHMS0.090 2ND COMPONENT 4TH SECONDARY
CRGSDC RESISTANCE RATING IN OHMS0.100 3RD COMPONENT 1ST SECONDARY
CRGSDC RESISTANCE RATING IN OHMS0.200 1ST COMPONENT 1ST SECONDARY
CRGSDC RESISTANCE RATING IN OHMS0.200 1ST COMPONENT SINGLE PRIMARY
CRMJWINDING POWER RATING0.2 VOLTS-AMPERES 3RD COMPONENT 1ST SECONDARY
CRMJWINDING POWER RATING18.03 VOLTS-AMPERES 2ND COMPONENT 4TH SECONDARY
CRMJWINDING POWER RATING3535.0 VOLTS-AMPERES 2ND COMPONENT 2ND SECONDARY
CWJSWINDING OPERATING VOLTAGE106.05 AC VOLTS NOMINAL 1ST COMPONENT 1ST SECONDARY
CWJSWINDING OPERATING VOLTAGE530.25 AC VOLTS NOMINAL 1ST COMPONENT 4TH SECONDARY
BKPLRATING METHODELECTRICAL 1ST COMPONENT 4TH SECONDARY
CRBZWINDING OPERATING CURRENT1.2 AMPERES DC NOMINAL 3RD COMPONENT 2ND SECONDARY
CRBZWINDING OPERATING CURRENT50.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 2ND SECONDARY
CRGSDC RESISTANCE RATING IN OHMS0.280 2ND COMPONENT SINGLE PRIMARY
CWJSWINDING OPERATING VOLTAGE106.05 AC VOLTS NOMINAL 1ST COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE130.00 DC VOLTS MINIMUM 3RD COMPONENT 2ND SECONDARY AND 137.00 DC VOLTS MAXIMUM 3RD COMPONENT 2ND SECONDARY
CWJSWINDING OPERATING VOLTAGE15.55 AC VOLTS NOMINAL 3RD COMPONENT SINGLE PRIMARY
CWJSWINDING OPERATING VOLTAGE16.26 AC VOLTS NOMINAL 3RD COMPONENT 1ST SECONDARY
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE ALL COMPONENTS
AEJNDISTANCE BETWEEN MOUNTING FACILITY CENTERS5.375 INCHES NOMINAL 3RD MOUNTING FACILITY SINGLE CENTER GROUP
AFHMMOUNTING TAB WIDTH0.625 INCHES NOMINAL
AXGYMOUNTING METHODTAB 3RD GROUP
BKPLRATING METHODELECTRICAL ALL COMPONENTS 2ND SECONDARY
CRBZWINDING OPERATING CURRENT50.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 1ST SECONDARY
CRGSDC RESISTANCE RATING IN OHMS0.200 1ST COMPONENT 3RD SECONDARY
CRGSDC RESISTANCE RATING IN OHMS1.200 2ND COMPONENT 1ST SECONDARY
CRGSDC RESISTANCE RATING IN OHMS2.750 1ST COMPONENT 4TH SECONDARY
CRMJWINDING POWER RATING5245.8 VOLTS-AMPERES 2ND COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE70.70 AC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY
TTQYTERMINAL TYPE AND QUANTITY36 WIRE LEAD
CWJSWINDING OPERATING VOLTAGE6.01 AC VOLTS NOMINAL 2ND COMPONENT 4TH SECONDARY
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABFEHAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONVIBRATION RESISTANT
ABHPOVERALL LENGTH6.030 INCHES MAXIMUM
ABTBMOUNTING HOLE DIAMETER0.500 INCHES NOMINAL 2ND GROUP
ACZBFREQUENCY RATING10.0 KILOHERTZ NOMINAL ALL COMPONENTS
ACZXWINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL 3RD COMPONENT AND INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL 3RD COMPONENT
AEJNDISTANCE BETWEEN MOUNTING FACILITY CENTERS4.500 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP
AKNAINCLOSURE TYPEFULLY INCLOSED
AKPVMOUNTING FACILITY QUANTITY2 1ST GROUP
AKPVMOUNTING FACILITY QUANTITY2 2ND GROUP
BKPLRATING METHODELECTRICAL 2ND COMPONENT 4TH SECONDARY
BKPLRATING METHODELECTRICAL ALL COMPONENTS 1ST SECONDARY
BKPLRATING METHODELECTRICAL ALL COMPONENTS SINGLE PRIMARY
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY 2ND COMPONENT AND 4 SECONDARY 2ND COMPONENT
CRBZWINDING OPERATING CURRENT0.01 AMPERES AC NOMINAL 3RD COMPONENT 1ST SECONDARY
CRBZWINDING OPERATING CURRENT0.035 AMPERES AC NOMINAL 3RD COMPONENT 3RD SECONDARY
CRBZWINDING OPERATING CURRENT30.0 MILLIAMPERES AC NOMINAL 1ST COMPONENT 4TH SECONDARY
CRGSDC RESISTANCE RATING IN OHMS0.040 3RD COMPONENT SINGLE PRIMARY
CRGSDC RESISTANCE RATING IN OHMS0.060 1ST COMPONENT 2ND SECONDARY
CRGSDC RESISTANCE RATING IN OHMS12.000 2ND COMPONENT 2ND SECONDARY
CRMJWINDING POWER RATING159.07 VOLTS-AMPERES 1ST COMPONENT 4TH SECONDARY
CRMJWINDING POWER RATING160.2 VOLTS-AMPERES 3RD COMPONENT 2ND SECONDARY
CRMJWINDING POWER RATING300.5 VOLTS-AMPERES 2ND COMPONENT 1ST SECONDARY
CRMJWINDING POWER RATING7.47 VOLTS-AMPERES 3RD COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE106.05 AC VOLTS NOMINAL 1ST COMPONENT SINGLE PRIMARY
CWJSWINDING OPERATING VOLTAGE14.14 AC VOLTS NOMINAL 2ND COMPONENT SINGLE PRIMARY
CWJSWINDING OPERATING VOLTAGE149.88 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE15.55 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY
CWJSWINDING OPERATING VOLTAGE178.16 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY AND 195.84 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY AND 213.57 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE6.01 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY

Relevant Components for NSN - 5950-01-339-8204, 5950013398204
5910-00-119-3109 (5910001193109) 5910-01-412-7751 (5910014127751) 5915-01-295-0462 (5915012950462) 5935-01-481-8464 (5935014818464)
5977-00-382-9167 (5977003829167) 5995-01-456-7631 (5995014567631) 5935-01-367-1819 (5935013671819) 5910-00-781-3808 (5910007813808)
5945-00-624-8204 (5945006248204) 5955-00-848-9495 (5955008489495) 5999-01-150-9025 (5999011509025) 5975-01-281-8807 (5975012818807)

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Semiconductor’s Certifications and Memberships

No China Banner
No China Parts The only independent
distributor with a
NO CHINA SOURCING Pledge
USA Flag Banner
USA Flag
  • All Orders are Fulfilled in the U.S.A.
  • All shipments must comply with U.S.A. export laws.
  • No exceptions.
Fallen Heros Banner
Fallen Heros Fund

“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.