We appreciate your interest in our selection of parts that fall under the NSN 5950-01-130-3608. Below, top-requested part numbers like TW65004-100, and others are presented alongside their manufacturer for your perusal. In order to receive pricing options on any featured NSN 5950-01-130-3608, simply click on the “RFQ” button next to it and complete the quote request form you are directed to. Be sure to include as many details as you can about your requirements and restrictions alike so our team can best formulate ideal fulfillment options for your consideration.
Owned and operated by the NSN parts supplier ASAP Semiconductor, National Stock Numbers Quotes is only stocked with items that meet strict regulatory and statutory guidelines for export compliance and quality assurance. Moreover, all NSN 5950-01-130-3608 items on this page are sourced from leading manufacturers that we trust and have vetted as necessary. Aside from this steadfast commitment, we also aim to address the unique constraints of customers wherever possible, even if other channels have failed to. If you have any further questions about the services we offer or wish to discuss your needs directly, our representatives are always just a call or email away from assisting you!
Item Name | Transformerassembly |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 01-130-3608 (011303608) |
NCB Code | USA (01) |
Manufacturer | Magnetika Inc |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
TW65004-100 | magnetika inc | transformerassembly | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC MAXIMUM 1ST COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC MAXIMUM 2ND COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES AC MAXIMUM 2ND COMPONENT SINGLE SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 400.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES AC MAXIMUM 1ST COMPONENT 4TH SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.0065 1ST COMPONENT 4TH SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.040 1ST COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.040 2ND COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.048 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.100 1ST COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.350 1ST COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 3.000 2ND COMPONENT SINGLE SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 3.000 3RD COMPONENT SINGLE SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; FIVE SECONDARY WINDINGS ON FIRST COMPONENT AND FOUR PRIMARY WINDINGS; ONE SECONDARY WINDING ON THIRD COMPONENT |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 17 PIN |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.600 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.985 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL ALL COMPONENTS |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL ALL COMPONENTS |
ADAQ | BODY LENGTH | 2.525 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.025 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.800 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AGAV | END ITEM IDENTIFICATION | MLRS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT ALL SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT ALL PRIMARY |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT SINGLE SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 5 SECONDARY 1ST COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT AND 1 SECONDARY 2ND COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 4 PRIMARY 3RD COMPONENT AND 1 SECONDARY 3RD COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM 1ST COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 140.0 MILLIAMPERES AC MAXIMUM 3RD COMPONENT SINGLE SECONDARY |
Relevant Components for NSN - 5950-01-130-3608, 5950011303608 | ||||
5998-01-213-3941 (5998012133941) | 5935-00-556-6808 (5935005566808) | 5999-01-461-2721 (5999014612721) | 5940-01-369-9814 (5940013699814) | |
5905-01-323-3631 (5905013233631) | 5930-00-691-2334 (5930006912334) | 5950-01-347-8845 (5950013478845) | 5990-00-631-1617 (5990006311617) | |
5905-01-477-6967 (5905014776967) | 5961-00-166-9940 (5961001669940) | 5998-00-483-3025 (5998004833025) | 5998-01-696-7523 (5998016967523) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote