We appreciate your interest in our selection of parts that fall under the NSN 5950-00-497-8949. Below, top-requested part numbers like 17-13045-1, 2006, and others are presented alongside their manufacturer for your perusal. In order to receive pricing options on any featured NSN 5950-00-497-8949, simply click on the “RFQ” button next to it and complete the quote request form you are directed to. Be sure to include as many details as you can about your requirements and restrictions alike so our team can best formulate ideal fulfillment options for your consideration.
Owned and operated by the NSN parts supplier ASAP Semiconductor, National Stock Numbers Quotes is only stocked with items that meet strict regulatory and statutory guidelines for export compliance and quality assurance. Moreover, all NSN 5950-00-497-8949 items on this page are sourced from leading manufacturers that we trust and have vetted as necessary. Aside from this steadfast commitment, we also aim to address the unique constraints of customers wherever possible, even if other channels have failed to. If you have any further questions about the services we offer or wish to discuss your needs directly, our representatives are always just a call or email away from assisting you!
Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 00-497-8949 (004978949) |
NCB Code | USA (00) |
Manufacturer | Lockheed Martin Corporation, Dyco Electronics Inc, Textron Systems Corporation |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
17-13045-1 | lockheed martin corporation | transformer power | RFQ |
2006 | dyco electronics inc | transformer power | RFQ |
17-13045-1 | textron systems corporation | transformer power | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.109 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.734 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.766 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.625 INCHES MINIMUM AND 2.750 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.250 INCHES MINIMUM AND 2.375 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.624 INCHES MINIMUM AND 3.812 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 450.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY12.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 12.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY56.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY46.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 56.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; SIX SECONDARY WINDINGS,ALL SECONDARY VOLTAGE AND CURRENT IS AFTER RECTIFICATION |
TEST | TEST DATA DOCUMENT | 80070-17-13045 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 24 SOLDER STUD |
Relevant Components for NSN - 5950-00-497-8949, 5950004978949 | ||||
5998-01-426-3956 (5998014263956) | 5998-01-050-0077 (5998010500077) | 5905-00-233-2726 (5905002332726) | 5999-01-087-2350 (5999010872350) | |
5975-01-078-1231 (5975010781231) | 5962-01-497-5083 (5962014975083) | 5925-00-850-1037 (5925008501037) | 5930-01-270-3588 (5930012703588) | |
5915-01-304-5062 (5915013045062) | 5998-00-437-4718 (5998004374718) | 5905-01-660-9208 (5905016609208) | 5970-01-593-6492 (5970015936492) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote