We appreciate your interest in our selection of parts that fall under the NSN 5950-00-492-9809. Below, top-requested part numbers like 1439, BE 10317-002, BE10317-001, and others are presented alongside their manufacturer for your perusal. In order to receive pricing options on any featured NSN 5950-00-492-9809, simply click on the “RFQ” button next to it and complete the quote request form you are directed to. Be sure to include as many details as you can about your requirements and restrictions alike so our team can best formulate ideal fulfillment options for your consideration.
Owned and operated by the NSN parts supplier ASAP Semiconductor, National Stock Numbers Quotes is only stocked with items that meet strict regulatory and statutory guidelines for export compliance and quality assurance. Moreover, all NSN 5950-00-492-9809 items on this page are sourced from leading manufacturers that we trust and have vetted as necessary. Aside from this steadfast commitment, we also aim to address the unique constraints of customers wherever possible, even if other channels have failed to. If you have any further questions about the services we offer or wish to discuss your needs directly, our representatives are always just a call or email away from assisting you!
Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 00-492-9809 (004929809) |
NCB Code | USA (00) |
Manufacturer | Basler Electric Company |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
1439 | basler electric company | transformer power | RFQ |
BE 10317-002 | basler electric company | transformer power | RFQ |
BE10317-001 | basler electric company | transformer power | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 6.500 INCHES NOMINAL6.500 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 8.750 INCHES NOMINAL8.750 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 5.250 INCHES NOMINAL5.250 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.370 INCHES NOMINAL SINGLE GROUP0.370 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT400.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND SLOT SINGLE GROUPSLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC NOMINAL SINGLE COMPONENT ALL PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 1.9 AMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY |
CRMJ | WINDING POWER RATING | 440.0 VOLTS-AMPERES SINGLE COMPONENT ALL SECONDARY500.0 VOLTS-AMPERES SINGLE COMPONENT ALL PRIMARY |
CRMJ | WINDING POWER RATING | 500.0 VOLTS-AMPERES SINGLE COMPONENT ALL PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 120.00 AC VOLTS MAXIMUM SINGLE COMPONENT ALL SECONDARY240.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 240.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TERMINAL BLOCK W/SCREWS |
Relevant Components for NSN - 5950-00-492-9809, 5950004929809 | ||||
5995-01-583-6913 (5995015836913) | 5905-00-225-2020 (5905002252020) | 5935-01-682-3961 (5935016823961) | 5985-00-880-3578 (5985008803578) | |
5935-01-284-5028 (5935012845028) | 5996-00-644-4427 (5996006444427) | 5930-01-356-0596 (5930013560596) | 5905-01-423-2384 (5905014232384) | |
5998-01-097-3169 (5998010973169) | 5930-00-490-4504 (5930004904504) | 5950-00-187-2893 (5950001872893) | 5998-01-076-5349 (5998010765349) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.