Components List of NSN (5950002397547) 5950-00-239-7547

We appreciate your interest in our selection of parts that fall under the NSN 5950-00-239-7547. Below, top-requested part numbers like 73C828-004, and others are presented alongside their manufacturer for your perusal. In order to receive pricing options on any featured NSN 5950-00-239-7547, simply click on the “RFQ” button next to it and complete the quote request form you are directed to. Be sure to include as many details as you can about your requirements and restrictions alike so our team can best formulate ideal fulfillment options for your consideration.

Owned and operated by the NSN parts supplier ASAP Semiconductor, National Stock Numbers Quotes is only stocked with items that meet strict regulatory and statutory guidelines for export compliance and quality assurance. Moreover, all NSN 5950-00-239-7547 items on this page are sourced from leading manufacturers that we trust and have vetted as necessary. Aside from this steadfast commitment, we also aim to address the unique constraints of customers wherever possible, even if other channels have failed to. If you have any further questions about the services we offer or wish to discuss your needs directly, our representatives are always just a call or email away from assisting you!

Item Name Transformer Power
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5950 Coils and Transformers
National Item Identification Number (NIIN) 00-239-7547 (002397547)
NCB Code USA (00)
Manufacturer Ail Systems Inc, Robert M Hadley Company Inc, Pulse Electronics Corporation
Part Number Manufacturer Item Name RFQ
73C828-004 ail systems inc transformer power RFQ
73C828-004 robert m hadley company inc transformer power RFQ
73C828-004 pulse electronics corporation transformer power RFQ

Technical Characteristics of NSN 5950002397547

MRCCriteriaCharacteristic
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.552 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 1.572 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP3.141 INCHES MAXIMUM SINGLE MOUNTING FACILIT
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.990 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 1.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP1.704 INCHES MAXIMUM SINGLE MOUNTING FACILIT
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP
ABKWOVERALL HEIGHT1.859 INCHES MINIMUM AND 1.891 INCHES MAXIMUM
ACZBFREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
ACZCINPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT
ACZDTRANSFORMER WINDING CONNECTION TYPEWYE-DELTA
ACZXWINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
ADAQBODY LENGTH3.859 INCHES MINIMUM AND 3.891 INCHES MAXIMUM
ADATBODY WIDTH2.172 INCHES MINIMUM AND 2.204 INCHES MAXIMUM
AEHZMAXIMUM OPERATING TEMP170.0 DEG CELSIUS
AEJNDISTANCE BETWEEN MOUNTING FACILITY CENTERS1.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP AND 1.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP
AKNAINCLOSURE TYPEFULLY INCLOSED
AKPVMOUNTING FACILITY QUANTITY2 1ST GROUP
AKPVMOUNTING FACILITY QUANTITY4 2ND GROUP
AKPVMOUNTING FACILITY QUANTITY4 3RD GROUP2 1ST GROUP
AKPVMOUNTING FACILITY QUANTITY4 4TH GROUP4 2ND GROUP
AXGYMOUNTING METHODTHREADED HOLE ALL GROUPINGS
BPLCWINDING FUNCTION AND QUANTITY2 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT
CQJXNOMINAL THREAD SIZE0.112 INCHES 2ND GROUP
CQJXNOMINAL THREAD SIZE0.112 INCHES 3RD GROUP0.138 INCHES 1ST GROUP
CQJXNOMINAL THREAD SIZE0.138 INCHES 1ST GROUP
CQJXNOMINAL THREAD SIZE0.164 INCHES 4TH GROUP0.112 INCHES 2ND GROUP
CRBZWINDING OPERATING CURRENT40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
CRBZWINDING OPERATING CURRENT40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
CRBZWINDING OPERATING CURRENT600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
CRBZWINDING OPERATING CURRENT84.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
CRMJWINDING POWER RATING1.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY5.46 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
CRMJWINDING POWER RATING1.8 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY41.52 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
CRMJWINDING POWER RATING41.52 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
CRMJWINDING POWER RATING5.46 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
CWJSWINDING OPERATING VOLTAGE1.038 AC KILOVOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY65.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
CWJSWINDING OPERATING VOLTAGE3.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY1.038 AC KILOVOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
CWJSWINDING OPERATING VOLTAGE39.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY
CWJSWINDING OPERATING VOLTAGE40.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY8.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY
CWJSWINDING OPERATING VOLTAGE65.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
CWJSWINDING OPERATING VOLTAGE8.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY39.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY
FEATSPECIAL FEATURESTWO PRIMARY WINDINGS; SIX SECONDARY WINDINGS
TESTTEST DATA DOCUMENT04660-73C828 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI
THSDTHREAD SERIES DESIGNATORUNC ALL GROUPINGS
TTQYTERMINAL TYPE AND QUANTITY25 TURRET

Relevant Components for NSN - 5950-00-239-7547, 5950002397547
5975-01-488-1039 (5975014881039) 5905-00-280-1812 (5905002801812) 5975-00-073-4207 (5975000734207) 5905-01-127-2056 (5905011272056)
5930-01-455-1402 (5930014551402) 5905-01-261-3683 (5905012613683) 5998-01-177-7709 (5998011777709) 5998-01-217-6701 (5998012176701)
5940-01-064-0053 (5940010640053) 5998-01-529-8918 (5998015298918) 5935-01-479-6289 (5935014796289) 5905-01-320-8479 (5905013208479)

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Semiconductor’s Certifications and Memberships

No China Banner
No China Parts The only independent
distributor with a
NO CHINA SOURCING Pledge
USA Flag Banner
USA Flag
  • All Orders are Fulfilled in the U.S.A.
  • All shipments must comply with U.S.A. export laws.
  • No exceptions.
Fallen Heros Banner
Fallen Heros Fund

“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.