We appreciate your interest in our selection of parts that fall under the NSN 5905-00-154-7022. Below, top-requested part numbers like 719-011-102, 123-1020, 3329P102, EC-0 125 490-2, 3329P1-102, and others are presented alongside their manufacturer for your perusal. In order to receive pricing options on any featured NSN 5905-00-154-7022, simply click on the “RFQ” button next to it and complete the quote request form you are directed to. Be sure to include as many details as you can about your requirements and restrictions alike so our team can best formulate ideal fulfillment options for your consideration.
Owned and operated by the NSN parts supplier ASAP Semiconductor, National Stock Numbers Quotes is only stocked with items that meet strict regulatory and statutory guidelines for export compliance and quality assurance. Moreover, all NSN 5905-00-154-7022 items on this page are sourced from leading manufacturers that we trust and have vetted as necessary. Aside from this steadfast commitment, we also aim to address the unique constraints of customers wherever possible, even if other channels have failed to. If you have any further questions about the services we offer or wish to discuss your needs directly, our representatives are always just a call or email away from assisting you!
Item Name | Resistor Variable Nonwire Wound |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 00-154-7022 (001547022) |
NCB Code | USA (00) |
Manufacturer | Andrew Scicomm Inc, Ddc Pertec Peripherals Corp, Trw Limited, Navy United States Department Of The, Bourns Instruments Inc, Iv Electronic Klaus Vespermann Kg, Mepcopal Co, Vishay Thin Film Llc, Raytheon Company, Interlink Communications Inc |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
719-011-102 | andrew scicomm inc | resistor variable nonwire wound | RFQ |
123-1020 | ddc pertec peripherals corp | resistor variable nonwire wound | RFQ |
3329P102 | trw limited | resistor variable nonwire wound | RFQ |
EC-0 125 490-2 | navy united states department of the | resistor variable nonwire wound | RFQ |
3329P1-102 | bourns instruments inc | resistor variable nonwire wound | RFQ |
65P102 | iv electronic klaus vespermann kg | resistor variable nonwire wound | RFQ |
8014EMB102E1 | mepcopal co | resistor variable nonwire wound | RFQ |
65P102 | vishay thin film llc | resistor variable nonwire wound | RFQ |
585094-7 | raytheon company | resistor variable nonwire wound | RFQ |
40-001029-07 | interlink communications inc | resistor variable nonwire wound | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | CYLINDRICAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 0.417 INCHES MAXIMUM |
ABJT | TERMINAL LENGTH | 0.187 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.270 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.165 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 0.270 INCHES MAXIMUM |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
AXGY | MOUNTING METHOD | TERMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 1.0 KILOHMS SINGLE SECTION |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
CQTM | TERMINAL LOCATION | REAR END |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0 TO 20.0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
TEST | TEST DATA DOCUMENT | 30890-40-00102 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
Relevant Components for NSN - 5905-00-154-7022, 5905001547022 | ||||
5935-01-100-9661 (5935011009661) | 5930-01-177-0618 (5930011770618) | 5950-01-304-9070 (5950013049070) | 5910-00-878-2060 (5910008782060) | |
5995-01-324-3546 (5995013243546) | 5961-00-458-7123 (5961004587123) | 5945-00-990-0283 (5945009900283) | 5930-01-243-8704 (5930012438704) | |
5962-01-337-0159 (5962013370159) | 5998-00-441-6985 (5998004416985) | 5935-00-727-4405 (5935007274405) | 5950-01-446-5153 (5950014465153) | |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote